Retrofit

Roughness Testers

The constant technological progress of measuring devices often leads to the obsolescence of these instruments that, even if still efficient and accurate in their mechanics, are old in terms of electronics and especially with regards to the interface software intended for the operator.

In these cases, a valid alternative instead of purchasing a new device, is to perform a Retrofit of the instrument. Through an interface kit, the mechanical and operational part of the original machine is kept, while PC controls and program are replaced with more recent applications, thus restoring the machine.

There are two types of retrofit that can be matched to a roughness tester; the first consists in connecting Profile Studio software for profile analyses to the original electronics with roughness module, while the second consists in replacing the management electronics as well, with one of latest generation. The last solution is adopted on extremely old devices or when failures on the existing electronics cannot be repaired.

The main feature of the retrofit kit is the Profile Studio software that allows to carry out all types of analyses and characterizations of the measured profile, which were unthinkable before with the old software, for example, on the same profile, it is possible to obtain the roughness analysis on an area and the geometric sizing of another.

Moreover, thanks to sophisticated internal algorithms, the updated profilometer improves accuracies since the software is able to pattern and therefore correct systematic measurement errors.

Basic components of a retrofit kit:

- Electronic basket (if required)

- Connection cables

- Profile Studio Sgftware

- Electric inter-connection diagrams (if required)

- User manual of the Profile Studio software

The retrofit of an old roughness tester can be considered an excellent alternative instead of purchasing a new instrument, because with a limited expense, you can restore an instrument that will be comparable with a new one, once updating is completed.

It is also possible to request the cleaning and complete inspection of the mechanical part of the instrument, performed by highly qualified staff.

Roundness Testers

Due to the obsolescence of software, constant update of reference laws and failures that may affect electronic boards, if often occurs that measurement instruments, even sophisticated ones like roundness testers, are still in good operating conditions with regards to the mechanical aspect, but are no longer suitable to perform characterizations of pieces. SM retrofit kits were conceived from this need, developed thanks to the extensive experience in the sector of industrial metrology.

The roundness tester retrofit is carried out by replacing the instrument’s existing electronics with one of new generation, that is connected with the same cables and connectors to the mechanical part of the roundness tester containing actuators and sensors. The instrument's update is concluded by installing the Circom software to analyse geometries, that is interfaced to the new electronics through USB.

Basic components of a retrofit kit:

- Electronic basket:

- Connection cables

- Circom Software

- Electric inter-connection diagrams (if required)

- User manual of the Circom software

The retrofit of an old roundness tester can be considered an excellent alternative instead of purchasing a new instrument, because with a limited expense, you can restore a device that will be comparable with a new one, once updating is completed.

It is also possible to request the cleaning and complete inspection of the mechanical parts of the instrument, performed by highly qualified staff.

Profilometers

The constant technological progress of measuring devices often leads to the obsolescence of these instruments that, even if still efficient and accurate in their mechanics, are old in terms of electronics and especially with regards to the interface software intended for the operator..

In these cases, a valid alternative instead of purchasing a new device, is to perform a Retrofit of the instrument. Through an interface kit, the mechanical and operational part of the original device is kept, while PC controls and program are replaced with more recent applications, thus restoring the machine.

There are two types of retrofit that can be matched to a profilometer; the first consists in connecting Profile Studio software for profile analyses to the original electronics, while the second consists in replacing the management electronics as well, with one of latest generation. The last solution is adopted on extremely old devices or when failures on the existing electronics cannot be repaired.

The main feature of the retrofit kit is the Profile Studio software that allows to carry out all types of analyses and characterizations of the measured profile, which were unthinkable before with the old software, in addition, thanks to internal sophisticated algorithms, the profilometer thus updated is more accurate since the software is able to pattern and therefore correct systematic measurement error.

Basic components of a retrofit kit:

- Electronic basket (if required)

- Connection cables

- Profile Studio Software

- Electric inter-connection diagrams (if required)

- User manual of the Profile Studio software

The retrofit of an old profilometer can be considered an excellent alternative instead of purchasing a new instrument, because with a limited expense, you can restore a device that will be comparable with a new one, once updating is completed.

It is also possible to request the cleaning and complete inspection of the mechanical parts of the instrument, performed by highly qualified staff.